The following formula should be used to calculate the total system flow rate.

 

System Flow Rate (gpm) =

         2.4 x Irrigated Area (feet2) x Emitter Flow Rate (gph)           
Emitter Spacing (inches) x Dripperline Spacing (inches)

 
Example:
  Irrigated Area =  7500 square feet
  Emitter Flow Rate = 1 gph
  Spacing Between Drip Emitters = 18"
  Spacing Between Dripperlines = 16"
Question:
   What is the system flow rate?
Solution:
System Flow Rate =

 2.4 x 7500 x 1
16 x 18

 = 62.5 gpm

The following formula may also be used.

System Flow Rate (gpm) =

  0.2 x Total Length of Dripperline (feet) x Emitter Flow Rate (gph)   
Emitter Spacing (inches)

 
Example:
  Total Length of Dripperline Used =  600 feet
  Emitter Flow Rate = 2 gph
  Spacing Between Drip Emitters = 12"
Question:
   What is the system flow rate?
Solution:
System Flow Rate =

 0.2 x 600 x 2
12

 = 20 gpm

Chart 7 offers a simpler method of calculating total flows. Calculate the total footage of DURA-FLOTM PC dripperline used, divide that by 100 and then multiply by the appropriate number in the chart.
 

Chart 7

Nominal Flow Per 100 Feet
Dripper Spacing 1/2 gph 1 gph 2 gph
12" 50 gph (.83 gpm) 100 gph (1.67 gpm) 200 gph (3.33 gpm)
18" 33 gph (.55 gpm) 67 gph (1.12 gpm) 133 gph (2.22 gpm)
24" 25 gph (.42 gpm) 50 gph (.83 gpm) 100 gph (1.67 gpm)